PROGRAM FIZCON VERSION 8.14                              Run on 04-Mar-2014

Input File Specification------------------------n-88-Ra-223.jeff32.stan
Check the Entire File
Sum Up Tests will be Performed
  Fractional Difference Allowed is  0.00500
Deviant Point Check will be Omitted
Consecutive Equal Value Check will be Omitted

TAPE BEING PROCESSED IS NUMBERED 7777
   LABEL IS  JEFF-3.2 Release - Neutron File March 2014                        


 Check material  88-Ra-223  MAT 8825


  ERROR(S) FOUND IN MAT=8825, MF= 1, MT=452
      
     CANNOT DO NU BAR SUMUP TEST DUE TO MISSING PARTIALS


     SUMUP TEST FAILED FOR TOTAL (MF= 3 AND MT=  1)

     THE FOLLOWING MTS WERE USED IN THE SUMUP TEST -   1   2   4  16  17  18
          37 102

     THE SUM OF PARTIALS DIFFERED FROM THE TOTAL BY MORE THAN   0.005000
          AT THE FOLLOWING POINTS

       ENERGY         TOTAL C-SECTION    (TOTAL)-(PARTIALS)         DELTA
   5.570750E+06        6.869370E+00       -5.073560E-02           -0.007386

 No problems to report
 Done FIZCON