BETHSY (IET facility)

Country:
France
Organization:
CEA - Commissariat à l'énergie atomique
Operating years:
1993 -
Reference reactor:
F-PWR-3L
Pictures:
IET25 picture #1 (PNG) IET25 picture #2 (PNG)

Main characteristics

Coolant:Water

Primary system volume:2.9 m3

Primary system pressure (max):17.2 MPa

Core flow area:0.043 m2

Scaling method:P-to-V(Kv)

Time scale:1

Volumetric scale:1/100

Height scale:1

Scaling approaches:

Loops

Number of loops:3

Number of single loops:3

HL inner diam.:118 mm

CL inner diam.:118 mm

Seal depth2.2 m

Number of FOR loops:1

Notes:

Preserv. Froude n

Primary pumps

Number:3

Fluid:2-phase

Coastdown:Controlled

Core

Number of sim. fuel Rods:428

Diameter:9.5 mm

Pitch:12.6 mm

Heated length:3.66 m

Max power:3 MW

Axial Peaking factor:1.6

Heating method:Indirect

Steam Generator

Number:3

Type:U Tube

Num. tubes single loop:34

Pressure:8 MPa

ID:19.7 mm

OD:22 mm

Pitch:32.5 mm

References