OTIS (IET facility)

Country:
United States of America
Organization:
B&W - Babcock & Wilcox
Operating years:
1984 -
Reference reactor:
B&W PWR Raised L - 2x4L
Pictures:
IET27 picture #1 (JPG)

Main characteristics

Coolant:Water

Scaling method:P-to-V(Kv)

Time scale:1

Volumetric scale:1/1686

Height scale:1

Scaling approaches:

Loops

Number of loops:1

Number of single loops:1

HL inner diam.:66.8 mm

Seal depth9.4 m

Number of FOR loops:1

Notes:

Preserv. Froude n

Core

Max power:0.18 MW

Steam Generator

Number:1

Type:OTSG

Num. tubes single loop:19

Pressure:8 MPa

ID:14.1 mm