UMCP (IET facility)

Country:
United States of America
Organization:
UMCP - University of Maryland College Park
Operating years:
-
Reference reactor:
B&W PWR Lowered L - 2x4L
Pictures:
IET29 picture #1 (JPG)

Main characteristics

Coolant:Water

Primary system volume:0.91 m3

Primary system pressure (max):2 MPa

Core flow area:0.03 m2

Scaling method:UMCP

Time scale:1

Volumetric scale:1/500

Height scale:0.33

Scaling approaches:

Loops

Number of loops:2

Number of single loops:2

HL inner diam.:89 mm

CL inner diam.:76 mm

Seal depth9.4 m

Number of FOR loops:2

Notes:

Preserv. Froude n

Core

Number of sim. fuel Rods:16

Diameter:25.4 mm

Pitch:80 mm

Heated length:0.6096 m

Max power:0.2 MW

Heating method:Indirect

Steam Generator

Number:2

Type:OTSG

Num. tubes single loop:28

Pressure:0.3 MPa

ID:30 mm

OD:31.7 mm

Pitch:50.8 mm

Average Tube length:3.9 m

References