GERDA (IET facility)

Country:
United States of America
Organization:
B&W - Babcock & Wilcox
Operating years:
- 1983
Reference reactor:
B&W PWR Raised L - 2x4L

Main characteristics

Scaling method:P-to-V(Kv)

Time scale:1

Volumetric scale:1/1686

Height scale:1

Scaling approaches:

Loops

Number of loops:1

Number of FOR loops:1

Notes:

Preserv. Froude n

Core

Max power:0.178 MW

Steam Generator

Number:1

Type:OTSG

Num. tubes single loop:19

References