DADINE (Vertical Tube, Inside) (SET facility)

CCVM Key:
3.7
Country:
France
Organization:
CEA - Commissariat à l'énergie atomique
Operating years:
-
Reference reactor:
Westinghouse PWR ;; FRAMATOME PWR
Availability:
Dismantled
Objectives:

Experimental conditions

Pressure min:0.1 MPa

Pressure max:0.6 MPa

Facility geometry

Keywords Others:

References

  • Ph. D. Thesis R. Freitas, University of Grenoble, 1981

  • Note CEA/DTE/SETh/LEML/87/60

  • B. Spindler, Reconstitution d'essais DADINE en regime permanent avec le code TRAC­ PF1/Mod1, Note CEA, DTE/SETh/LEML/87-60, 1987


Phenomena

Relevance Phenomenon
50%
Entrainment and Deentainment
100%
Heat Transfer : Core
100%
Heat Transfer : SG
50%
Phase separation