TPFL/INEL Tee Critical Flow (SET facility)

CCVM Key:
11.35
Country:
United States of America
Organization:
INEL - Idaho National Engineering Laboratory (INEL)
Operating years:
-
Reference reactor:
Availability:
Objectives:

Experimental conditions

Pressure min:2 MPa

Pressure max:6 MPa

Temperature min:20 °C

Temperature max:275 °C

Facility geometry

Keywords Steam Separator:

Keywords Others:

References

  • Final Design Report for the LOFT Two-Phase Flow Calibration Loop, C L Nalezny. EG&G Idaho, November 1980

  • J. L. Anderson and W. A. Owca, Data Report for the TPFL Tee/Critical Flow Experiments, NUREG/CR-4164, EGG-2377, 1985


Phenomena

Relevance Phenomenon
100%
Break Flow
100%
Phase separation