G2/W (SET facility)

CCVM Key:
11.49
Country:
United States of America
Organization:
Westinghouse - Westinghouse
Operating years:
-
Reference reactor:
Availability:
Objectives:
Pictures:
SET179 picture #1 (PNG) SET179 picture #2 (PNG) SET179 picture #3 (PNG)

Main characteristics

Number of simulated fuel rods:289

Experimental conditions

Test details:

The test was initiated by filling the test vessel to a specified level with saturated water from the accumulators or the flash chamber. The power was then turned on and data acquisition began. The water began to boil away, generating a two-phase mixture, and the rods were slowly uncovered from the top down. As the rods were uncovered, the emperature of the rods suddenly increased. The power as turned off when the rod temperature reached the maximum allowable temperature of 1580°F (860°C), or when the rods were uncovered below the 69 in. (1.75 m) level. After the power was turned off, data taking continued for 30 seconds; the test was then terminated.

Pressure min:0.1 MPa

Pressure max:5.51 MPa

Temperature max:860 °C

Power min:250 kW

Power max:1250 kW

Facility geometry

Keywords Steam Separator:

Keywords Others:

References


Phenomena

Relevance Phenomenon
100%
Heat Transfer : Core
100%
Heat Transfer : SG
100%
Phase separation