Blowdown Heat Transfer RS 37 (SET facility)

CCVM Key:
4.5
Country:
Germany
Organization:
KWU - Kraftwerk Union AG (KWU)
Operating years:
-
Reference reactor:
Availability:
Objectives:

Main characteristics

Number of simulated fuel rods:25

Heat method:Direct

Experimental conditions

Pressure max:15 MPa

Facility geometry

Keywords General:

Keywords Core:

Keywords Others:

References

  • Agemar. F.; Brand, B.; Emmerling, R.: "DWR Hauptversuche mit einem 25 Stabbundel, Teil 1: Experimentelle Durchfuhrung und Dokumentation der Merssergebnisse". KWU RE 23/012/77, Erlangen 1977.


Phenomena

Relevance Phenomenon
100%
Heat Transfer : Core
100%
Heat Transfer : SG