Browse

SET Facilities (fully or partially suitable for model validation)

RelevanceRel. CCVM SET Facility Description
100% 8.4   120-bar Loop [8.4] Description
100% 5.7   8x8 Bundle, CISE [5.7] Description
100% 11.47   ANL Power -Void Transf. Funct. BWR [11.47] Description
100% 7.1   BCN Boiloff/Reflood Tests (36 rods) [7.1] Description
100% 4.5   Blowdown Heat Transfer RS 37 [4.5] Description
100% 10.20   Boiler Dynamics Rig [10.20] Description
100% 5.12   CHF ENEA [5.12] Description
100% 11.10   Columbia rod Bundle Blowdown HT [11.10] Description
100% 3.7   DADINE (Vertical Tube, Inside) [3.7] Description
100% 3.12   ERSEC Tube (Inside) [3.12] Description
100% 11.23   FLECHT SEASET Westinghouse [11.23] Description
100% 11.29   FLNCF/SRI 4 Loop Natural Circulation [11.29] Description
100% 8.3   FRIGG/FROJA [8.3] Description
100% 11.49   G2/W [11.49] Description
100% 8.1   GOTA BWR ECC Tests [8.1] Description
100% 12.1   HALDEN Reactor. Reflood Tests [12.1] Description
100% 11.21   HCNTL/UC [11.21] Description
100% 6.16   HICOF (Hitachi Core and Fuel Test Loop) [6.16] Description
100% 4.6   Heat Transfer Refill/Reflood RS 36 [4.6] Description
100% 5.4   JETI-4 Fuel Channel SIET [5.4] Description
100% 11.20   JLTF/W [11.20] Description
100% 11.42   LEHIGH Post CHF Heat Tr. Bundle [11.42] Description
100% 11.57   LEHIGH Post CHF Vertical Tube [11.57] Description
100% 11.56   LTSF Blowdown Quench/INEL [11.56] Description
100% 11.52   MB-2 SG Transient/Westinghouse [11.52] Description
100% 10.23   Multipin Cluster Rig [10.23] Description
100% 9.1   NEPTUN-I Boiloff [9.1] Description
100% 3.15   OMEGA Rod Bundle [3.15] Description
100% 3.14   OMEGA Tube (Inside) [3.14] Description
100% 3.11   PATRICIA GV 2 [3.11] Description
100% 10.4   Post Dryout Ins. Tube (HP, Winfrith) [10.4] Description
100% 10.7   Post Dryout Ins. Tube (LP, Harwell) [10.7] Description
100% 10.3   REFLEX Tube Reflood [10.3] Description
100% 6.10   RRTF (Refill/Reflood Test Facility) Toshiba [6.10] Description
100% 4.9   Rewet RS 62/184 [4.9] Description
100% 11.25   SCTF/UCLA [11.25] Description
100% 6.11   SHTF (Spray Heat Transfer Test Facility) Toshiba [6.11] Description
100% 11.40   SSCALE/INEL Semiscale [11.40] Description
100% 11.12   SUNYAB [11.12] Description
100% 11.11   State Univ. New York at Buffalo [11.11] Description
100% 4.7   Steady State DNB Exp RS 164 [4.7] Description
100% 11.3   THEF Post CHF Ins. Tube [11.3] Description
100% 11.38   THTF/ORNL [11.38] Description
100% 10.5   TITAN/9MW Rigs [10.5] Description
100% 6.1   TPTF, JAERI [6.1] Description
100% 11.30   U-Tube SG Two-Loop Test Fac/SRI [11.30] Description
100% 11.9   UCB [11.9] Description
100% 11.24   UCLA [11.24] Description
100% 11.7   UCSB Vert Tube [11.7] Description
100% 11.8   Univ. California B. Tube Reflood [11.8] Description
50% 10.1   ACHILLES Reflood Loop [10.1] Description
50% 11.41   BWR-FLECHT/GE [11.41] Description
50% 10.32   Low Pressure Boiling Fac. (Harwell) [10.32] Description
50% 11.48   Natural Circulation Boiling/ANL [11.48] Description
50% 10.22   Single Pin Reflood [10.22] Description
50% 4.8   Trans. Boil. Inst. Tube (Freon) RS 370 [4.8] Description

CFD Facilities (fully or partially suitable for model validation)

No CFD facilities